Winterwarm productcatalogue and pricelist

Winterwarm heating solutions With this brochure you can simply select all necessary parts for a Winterwarm heating installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product catalogue and pricelist 1. July 2025 - 1. July 2026 Winterwarm-quality • More than 90 years of experience • ISO 9001:2015 certified • Quick delivery • Reliable

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Prices in this catalogue are gross prices. All previous price lists hereby become void; price changes and printing/ typesetting errors are subject to change. For net prices you can contact the export department in the Netherlands, or the Winterwarm distributor in your country (check www.winterwarm.com for names and addresses or call +31.543.546300) Version: 1. July 2025 - valid untill 1. July 2026

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Winterwarm HR Condensing unit air heater page 14 / 15 Winterwarm Qwikshift Heat pump combined with innovative booster technology page 6 / 11 WWH LT + HPX a full electric heating and cooling solution page 12 Winterwarm WinterCooler industrial air cooler for cooling large spaces page 13 Winterwarm HR-EC Condensing unit air heater with EC-fan page 16 / 17 Winterwarm XR+ Indirect fired unit air heater with modulating burner and fan page 18 / 19 Controls page 36 / 37 Winterwarm DX-EH Electric air heater, specifically for sustainable heating of stables page 38 / 39 About us Winterwarm, quality all over page 4 / 5 Winterwarm Water heater LT for low water temperatures page 30 / 31 Winterwarm JET powerful air heater for high spaces page 32 / 33 Winterwarm EH electric heater page 34 / 35 Winterwarm DXE Indirect fired air heater for installation outside the poultry house page 42 / 43 Winterwarm DHX Direct gas fired heater for poultry houses and glass houses page 44 / 45 Winterwarm DXF For optimal air distribution in poultry houses or glass houses page 47 Winterwarm DXC Indirect fired air heater with closed combusition system for poultry houses page 40 / 41 Winterwarm ACM Air curtain consisting of separate modules page 22 / 23 Flue material page 20 / 21 Winterwarm Water heater page 26 / 27 Destratification fans page 24 / 25 Winterwarm DXB Direct oil fired heater for poultry houses page 46 / 47 Winterwarm Water heater EC page 28 / 29

4 EURO-AIR European Association of Air Heater Manufacturers For almost 90 years now, Winterwarm has been engaged in the development, production and sales of heating systems for the industrial, agricultural and retail markets. We achieved a leading position in the European market by focusing on three things: quality, service and innovation. We are proud of our program of high end, sustainable products among which air heaters, heat pumps, air curtains, thermostats and more, which all contribute to a comfortable climate in buildings at an efficient energy consumption. Whether it is a warehouse, a poultry house, a factory or a supermarket. Looking forward to a sustainable future With all expertise we have gathered in the past years Winterwarm can play an important role in the energy transition. We continuously do research for new “green” heating solutions with a low carbon footprint and try to improve our existing product program. At this moment Winterwarm offers various sustainable heating solutions such as hybrid heaters (heat pump + booster), electric air heaters and water-supplied air heaters (in combination with a heating network, heat pump or boiler). When solar panels are present, our electric heater EH (industrial) or DX-EH (agricultural) are a good solution for the sustainable heating of industrial premises c.q. poultry houses. And where a gas-fired unit air heater is still the best solution for the moment, we have high-efficiency condensing air heaters HR available or for in poultry houses the efficient DXC gas fired heaters. Sustainable in day-to-day business In addition to manufacturing sustainable heating solutions for our customers, our new factory is the most sustainable building in Winterswijk, Green Leaf municipality 2022 herself. The new business premises has received a BREEAMOutstanding certificate, which means that it meets various sustainability criteria at the highest level. A number of those criteria concern health, energy use, circularity of materials, land use and ecology. We are very happy to be able to take the next steps towards sustainable heating in this beautiful building together with our sister company WinLed Lighting Solutions.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Winterwarm World Wide 5 High quality product development Winterwarm has its own R&D department which continuously works on the development of new products and the improvement of existing ones. Our goal is to provide our customers with a reliable product of high quality for a reasonable price. Our product range consists of 90% products which we engineered ourselves in the past 20 years, for as well the industrial market as the agricultural market. At this moment our R&D focuses on the development of sustainable heating solutions. Quality from top to bottom Since 1992, Winterwarm has been ISO certified (ISO 9001:2015). Periodically the whole process of product engineering and development, production, delivery and after-sales service is audited by KIWA (the national gas institute in the Netherlands). Consequently, we continuously work to improve all aspects of our company processes. Before a heater leaves our factory, it is submitted to an extensive final test. This provides extra assurance to the installer and his customer that the heater will function well immediately after installation. Van Marcke - HVAC wholesaler Roeselaere, Belgium 4x XR 60 heaters in VAM store Vauxhall garage Sheffield, United Kingdom 6.900 m2 - XR + TR + WCU Hennes & Mauritz distribution centre Poznan, Poland 80.000 m2 - 107x XR + TR Project in Ireland by JF McKenna. New poultry house with 50.000 chickens with 4 DXE heaters. Jevansa Poultry - Erp (NL) 3 poultry houses with each 4 DXC heaters for in total 120.000 chickens.

Qwikshift QSE 6 A B C D E QSE 6+x 550 640 805 - - QSE 12+x - - - 1200 1200 QSE 16+x - - - 1200 1200 x=type boosterunit 2 1 A B C D E F G H I J K L M QSE 6+x 716 422 508 405 495 663 305 471 302 65 465 302 350 QSE 12+x 884 563 836 540 670 795 413 625 301 65 625 219 490 QSE 16+x 1083 563 836 540 670 794 410 825 299 65 825 219 490 x=type boosterunit + Measurements Qwikshift QSE booster unit 3 4 front view top view bottom view Smart Grid ready Winterwarm Qwikshift QSE The Qwikshift Hybrid Heater is the latest solution for sustainable heating of industrial buildings, shops and warehouses. A heat pump, combined with an innovative booster technology realises quickly the desired room temperature. The QSE booster unit is provided with a water coil for heat transfer or cooling using a heatpump, and an electric booster for extra heat at the coldest moments. The smart controller allows you to heat as economically as possible and save on monthly recurring energy costs. Characteristics • all-electric • silent and energy-saving EC fan • quick heating by booster • sustainable heating solution • can be combined with solar panels • cooling to min. water temperature of 7°C • no CO2 emissions • supplied including Smart Controller • no buffer tank required Sustainable choice The Smart Controller ensures that you use your energy smartly and therefore energy efficiently. • Modbus connection • Wifi control • Automatically optimum heating mode after entering current energy prices • Up to 4 heaters per controller • External temperature sensor possible • Day/night control • Cooling function • Available languages: NL/DE/EN/FR/PL 1

7 Technical data QSE-series Type Price (incl. Smart Controller) € 6615 7055 7225 7385 7185 7710 7850 8095 8730 9120 Total heating capacity kW 15,9 21,0 27,0 41,7 20,7 25,6 30,7 35,5 45,4 55,3 Type corresponding heat pump* HPX 06 HPX 06 HPX 12 HPX 12 HPX 16 HPX 16 HPX 16 HPX 16 HPX 16 HPX 16 Maximum power heat pump** kW 6,0 12,0 12,0 12,0 15,7 15,7 15,7 15,7 15,7 15,7 Minimum power heat pump** kW 2,4 2,4 4,8 4,8 6,3 6,3 6,3 6,3 6,3 6,3 Maximum power Booster kW 9,9 15,0 15,0 29,7 5,0 9,9 15,0 19,8 29,7 39,6 Minimum power Booster kW 3,3 7,5 7,5 10,0 2,5 3,3 7,5 10,0 10,0 20,0 Cooling capacity*** kW 6,5 6,5 12 12 15,4 15,4 15,4 15,4 15,4 15,4 Air output max. power (warm) m³/h 1800 1800 4500 4500 6700 6700 6700 6700 6700 6700 Throw horizontal (max.) m 15 15 20 20 25 25 25 25 25 25 Voltage indoor unit (50hz) V 230V of 400V+N 400V+N 400V+N 230V of 400V+N 400V+N 400V+N 400V+N 400V+N 400V+N 400V+N Max. electrical current booster, per phase A 15,8 23,2 23,3 44,6 14,1 17,5 24,9 31,9 46,2 60,6 Max. electrical current booster, one phase A 44,5 n/a n/a n/a 24,9 46,2 n/a n/a n/a n/a Electrical current outdoor unit (max.) A 11,0 11,0 11,5 11,5 12,5 12,5 12,5 12,5 12,5 12,5 Weight kg 47 48 83 88 100 102 104 106 110 114 Water connection (ext.) G” 3/4 3/4 1 1 1 1 1 1 1 1 Water volume coil L 2,0 2,0 3,9 3,9 6,6 6,6 6,6 6,6 6,6 6,6 Sound level dB(A) 35-54 35-54 35-63 35-62 35-62 35-62 35-62 35-62 35-62 35-62 *) The QSE booster unit and the heat pump should be ordered separately; the booster unit is supplied with Smart Controller included **) At water temperatures 35°C/30°C and room temperature 20°C, according to EN1397. ***) At water temperatures 12°/17°C, room temperature 27°C, 50% RH, according to EN1397. Accessories QSE-serie Type applicable on article no. price € Heat pump HPX 06 QSE 6+10/15 GHW8000 3860 Heat pump HPX 12 QSE 12+15/30 GHW8006 4960 Heat pump HPX 16 QSE 16+x GHW8008 5380 Smart Controller, as standard supplied together with the QSE booster unit all QSE types IW8050 - Power isolation switch for inside and outside 230 V -400V. 25 Amp all QSE types IK5281 82 Power isolation switch 400V, 63 Amp. QSE 12+30/40 en QSE 16+30/40 IE5210 225 Roof duct for heat pump ø100mm all QSE types IW8032 131 Suspension brackets S QSE 6+10/15 GA8610 195 Suspension brackets M QSE 12+x en QSE 16+x GA8580 204 Suspension kit for heatpump incl. 4 vibration dampers (for wall suspension) HPX 06-12-16 GA8650 237 Set vertical louvres (4 pcs.) QSE 6+10/15 GX2003 126 Set vertical louvres (4 pcs.) QSE 12+15/30 GX4002 127 Set vertical louvres (5 pcs.) QSE 16+x GX6004 194 x = type booster 5 - 10 - 15 - 20 - 30 - 40 1 1 2 2 3 3 Electric booster EC fan for minimal electricity consumption Water to air heat exchanger coil 1 2 3 4 Unit QSE 6+10 QSE 6+15 QSE 12+15 QSE 12+30 QSE 16+5 QSE 16+10 QSE 16+15 QSE 16+20 QSE 16+30 QSE 16+40

Qwikshift QSG 1 2 3 Measurements Winterwarm Qwikshift QSG The Qwikshift Hybrid Heater is the latest solution for sustainable heating of industrial buildings, shops and warehouses. A heat pump, combined with an innovative booster technology realises quickly the desired room temperature. The QSG booster unit is provided with a water coil for heat transfer or cooling using a heatpump, and a gas fired booster for extra heat at the coldest moments. The smart control allows you to heat as economically as possible and save on monthly recurring energy costs. Characteristics • gasfired • quick heating by booster • sustainable heating solution • up to 60% reduced energy consumption • hydrogen ready • cooling to min. watertemperature of 7°C • up to 70% less CO2 emissions • silent and energy-saving EC fan • no buffer tank required • supplied including Smart Controller 2 A B C D E F G H I J K L M N O P Q QSG 6+x 716 422 508 405 495 813 455 465 302 65 465 302 455 94 108 110 401 QSG 12+x 884 563 636 540 670 944 560 625 298 65 625 219 640 114 117 110 536 QSG 16+x 1083 563 836 540 670 944 560 824 298 65 825 219 640 114 117 110 536 x=type boosterunit + 1 8 A B C D E QSG 6+x 550 640 805 - - QSG 12+x - - - 1200 1200 QSG 16+x - - - 1200 1200 x=type boosterunit 4 3 1 The Smart Controller ensures that you use your energy smartly and therefore energy efficiently. • Modbus connection • Wifi control • Automatically optimum heating mode after entering current energy prices • Up to 4 heaters per controller • External temperature sensor possible • Day/night control • Cooling function • Available languages: NL/DE/EN/FR/PL Smart Grid ready Sustainable choice 1 2 3 Patented heat exchanger booster EC fan for minimal electricity consumption Water to air heat exchanger coil

9 Technical data Qwikshift QSG Type Price (incl. Smart Controller) € 8270 8820 9925 10475 11575 11155 11710 12810 13915 Total heating capacity kW 18,0 25,2 31,2 41,0 50,8 34,9 44,7 54,5 64,0 Type corresponding heat pump* HPX 06 HPX 06 HPX 12 HPX 12 HPX 12 HPX 16 HPX 16 HPX 16 HPX 16 Maximum power heat pump** kW 6,0 6,0 12,0 12,0 12,0 16,0 15,7 15,7 15,7 Minimum power heat pump** kW 2,4 2,4 4,8 4,8 4,8 6,3 6,3 6,3 6,3 Maximum power Booster kW 12,0 19,2 19,2 29,0 38,8 19,2 29,0 38,8 48,3 Minimum power Booster kW 4,2 6,4 9,0 9,5 12,8 9,5 9,5 12,8 15,9 Cooling capacity*** kW 6,5 6,5 12 12 12 15,4 15,4 15,4 15,4 Air output max. power (warm) m³/h 1800 1800 4500 4500 4500 6700 6700 6700 6700 Throw horizontal (max.) m 15 15 20 20 20 25 25 25 25 Voltage indoor unit (50hz) V 230V 230V 230V 230V 230V 230V 230V 230V 230V Max, electrical current booster, per phase A 1,5 1,5 1,6 1,6 1,6 3,2 3,2 3,2 3,2 Electrical current outdoor unit (max.) A 11,0 11,0 11,5 11,5 11,5 12,5 12,5 12,5 12,5 Weight kg 57 62 120 120 125 145 145 155 160 Gas consumption G25 m³/h 1,3 2,1 2,1 3,2 4,2 2,1 3,2 4,2 5,3 Gas consumption G20 m³/h 1,5 2,4 2,4 3,6 4,8 2,4 3,6 4,8 6,0 Gas consumption propane G31 kg/h 1,0 1,6 1,6 2,4 3,2 1,6 2,4 3,2 4,0 Water connection G” 3/4 3/4 1 1 1 1 1 1 1 Water volume coil L 2 2 3,9 3,9 3,9 6,6 6,6 6,6 6,6 Sound level dB(A) 35-54 35-54 35-62 35-63 35-63 35-61 35-62 35-62 35-62 Nox-emission (GCV) mg/kWh 30 21 14 33 40 14 33 40 31 Flue terminal length (max.) m 9 9 9 9 9 9 9 9 9 *) The QSG booster unit and the heat pump should be ordered separately; the booster unit is supplied with Smart Controller included **) At water temperatures 35°C/30°C and room temperature 20°C, according to EN1397. ***) At water temperatures 12°/17°C, room temperature 27°C, 50% RH, according to EN1397. 1 2 3 4 ød øD HOH A B E F QSG 80 125 110 1370 575 610 135 Unit QSG 6+10 QSG 6+20 QSG 12+20 QSG 12+30 QSG 12+40 QSG 16+20 QSG 16+30 QSG 16+40 QSG 16+50 Accessories QSG-series Type applicable on article no. price € Heat pump HPX 06 QSG 6+10/20 GHW8000 3860 Heat pump HPX 12 QSG 12+20/30/40 GHW8006 4960 Heat pump HPX 16 QSG 16+x GHW8008 5380 Smart Controller, as standard supplied together with the QSG booster unit all QSG types IW8050 - Power isolation switch for inside and outside 230 V - 400 V, 25 Amp. all QSG types IK5281 82 Roof duct for heat pump ø100mm all QSG types IW8032 131 Suspension brackets S QSG 6+10/20 GA8610 195 Suspension brackets M QSG 12+x en QSG 16+x GA8580 204 Suspension kit for heatpump incl. 4 vibration dampers (for wall suspension) HPX 06-12-16 GA8650 237 Set vertical louvres (4 pcs.) QSG 6+10/20 GX2003 126 Set vertical louvres (4 pcs.) QSG 12+20/30/40 GX4002 127 Set vertical louvres (5 pcs.) QSG 16+x GX6004 194 DDV 80/125 HR Roofterminal* all QSG types IA8214 175 CT 80/125 HR Wall terminal* all QSG types IA8216 149 x = type booster 20 - 30 - 40 - 50 *) For more flue material see page 20/21 Flue terminals

HPX heat pump 1 4 5 6 F G H HPX 06 700 1063 700 HPX 12 700 1120 700 HPX 16 700 1120 700 3 2 10 Winterwarm HPX Heat pump The Winterwarm HPX Heat pumps are efficient air/water heat pumps meant to apply in combination with the indoor unit of the Qwikshift Hybrid Heater. The HPX is the outdoor unit, either to be placed on the roof or be attached to the wall. The HPX can also be applied together with water heaters like the WWH-LT. This air heater is especially engineered for low water temperatures and therefore very suitable to be connected to a heat pump (see page 28). Characteristics • high COP value of >5 • applicable between -25°C en +35°C • Energy class A*** • heats and cools • 4 capacities • environment friendly refrigerant R32 • internal expansion tank • internal circulation pump • DC-fan • modulating compressor • water circulation filter included • frostprotection Measurements A B C D E F øG HPX 06 1150 735 365 415 1036 302 10 HPX 12 1206 878 445 490 1120 355 12 HPX 16 1206 878 445 490 1120 355 12 HPX 30 1338 1950 588 580 1130 355 12 7 Sustainable choice

11 1 2 3 5 4 6 7 Accessories HPX-series* Type applicable on article no. price € Power isolation switch for inside and outside HPX 06-12-16 IK5281 82 Anti-frost valve (2x per heat pump) HPX 06-12-16 IW8040 281 Roof duct HPX 06-12-16 IW8032 131 Rubber setup block + attachments, 2 pcs - L600 - H95mm HPX 06-12-16 IW8043 116 Rubber block for extra height, 1 pc - L=600mm-H=120mm HPX 06-12-16 IW8044 92 Brackets for attachment to the wall, incl. 4 vibration dampers HPX 06-12-16 GA8650 237 Modbus expansion set HPX 06-12-16 GA8010 504 *) The HPX is as standard provided with an expansion vessel (inside the heat pump), water filter and venting. Technical data HPX-series Type Unit HPX 06 HPX 12 HPX 16 HPX30 Price € 3860 4960 5380 8505 Heating capacity* kW 6,0 12,0 15,7 30 Cooling capacity** kW 6,5 12,0 15,7 31 Absorbed electrical power kW 1,11 2,49 3,57 7.56 COP* 5,41 4,82 4,40 4,35 Energy classroom heating** (811/2013/EU) A+++ A+++ A+++ A+++ Refrigerant R32 R32 R32 R32 Refrigerant contents kg 0,95 2,2 2,2 5 Net weight kg 90 144 144 261 Water connection ” 1” 1” 1” 1½” Voltage outdoor unit (50hz) V 230 3x400 3x400 3x400 Electrical current outdoor unit (max) A 11,0 11,5 12,5 21,7 Max. sound level, in operation db(A) 58 54 56 58 Protection degree IPX4 IPX4 IPX4 IPX4 Outdoor temperature range heating modes ºC -25/35 -25/35 -25/35 -25/35 Contents internal expansion vessel L 2 3 3 10 Venting + overflow included yes yes yes yes Water circulation filter yes yes yes yes *) At 7°C outside temperature and 30/35°C water temperature, according to EN 14511. **) At 35°C outside temperature and 23/18°C water temperature, according to EN 14511. Inside unit QS types Heat pump QSG 6+20 HPX 06 QSG 12+30 HPX 12 QSG 16+40 HPX 16 QSE 6+10 HPX 06 QSE 12+30 HPX 12 QSE 16+10 HPX 16 QSE 16+15 HPX 16 WWH 110 LT HPX 06/HPX 12 WWH 220 LT HPX 12/HPX 16 WWH 330 LT HPX 16/HPX 30 WWH 340 LT HPX 30 JET 220 HPX 16 JET 330 HPX 16/HPX 30 JET 340 HPX 30 Heat emission systems

WWH LT-series with HPX heatpump WWH-LT is a waterheater that, in combination with the HPX heat pump, forms an all-electric heating solution that can also provide cooling. Alongside the QSE and QSG, it is one of the most sustainable heating solutions for larger commercial or industrial spaces. The control of the heat pump and the WWH-LT can be managed using a Modbus expansion set or with a simple 0-10V signal, for example, centrally via a building management system. Characteristics • compatible with the Winterwarm HPX heat pump • equipped as standard with an EC fan (quiet and energy-efficient) • heating capacity from 6 to 30 kW (at 35°/30° and 15°C room temperature) • cooling capacity from from 6,5 kW to 31 kW (at 18°/23° and 35°C outside temperature) • stepless fan control to adjust air volume • standard built-in condensate drip tray • condensate pump bracket available as an accessory (required for cooling) • can be controlled via a building management system WWH LT + HPX 12 Smart Controller (IW8050) Condensate pump + bracket obligatory for cooling (GX8024) Modbus expansion set (GA8010) Control possibilities A WWH-LT without building management system B WWH-LT with building management system and HPX heat pump A B Technical data* Type Unit WWH 110LT WWH 220LT WWH 330LT WWH 340LT Article no. GI110WWLEC GI220WWLEC GI330WWLEC GI340WWLEC Price € 1700 2280 3270 3980 Compatible heat pump HPX** HPX06/HPX12 HPX12/HPX16 HPX16/HPX30 HPX30 Max. heating capacity (at 35°/30°C and kW 6,0/12,0 12,0/15,7 15,7/30 30 15°C room temperature), per type heat pump Max. cooling capacity (at 18°/23°C and kW 6,5/12 12/15,7 15,7/31 31 35°C outside temperature), per type heat pump Air volume (maximal) m3/h 1850 4150 5450 8650 Throw (horizontal, warm) m3/h 14 21 20 25 Sound level (@5 meter) dB(A) 35-54 35-64 35-60 35-62 *) for more technical data see page 31 Accessories Description article no. price € Modbus expansion set GA8010 504 Smart Controller IW8050 586 Condensate pump + bracket (obligatory when cooling) GX8024 265

CL250 CL450 CL650 WinterCooler Winterwarm WinterCooler In addition to various heating solutions, Winterwarm is increasingly offering cooling options (QSE, QSG, WWH-LT). The WinterCooler is an industrial air cooler designed to provide simple and efficient cooling for large spaces - ideal for those looking to bring down the temperature during the hottest days of the year. It is a flexible and environmentally friendly solution based on adiabatic cooling. Characteristics • suitable for areas up to 650 m² • adjustable airflow volume • easy to move (2 fixed and 2 swivel wheels) • water tank capacity sufficient for 8–12 hours of operation • automatic pump shut-off when water level is low • UV filter for water hygiene included as standard • no water vapour formation • dust-reducing effect • user-friendly control panel • stepless fan control • single-phase power supply • plug-andplay (230 V) • removable panels for easy cleaning • 2-year warranty 13 Technical data WinterCooler Type Unit CL250 CL450 CL650 Price € 6300 7825 10765 Cooling capacity (max.) m2 250 450 650 Throw m 17-22 25-30 30-36 Air volume m3/h 23.000 32.000 48.000 Electrical current A 4,5 6,9 7,6 Energy consumption (max.) kWh 0,75kWh 0,96kWh 1,1kWh Voltage V 230-50/60Hz,1F 230- 50/60Hz, 1F 230-50/60Hz, 1F Motor kW 1,10 1,11 1,49 Sound level dB(A) 50-75 50-75 75 Water reservoir L 130 180 230 Weight kg 50 120 160 Dimensions cm (wxdxh) 112 x 64 x 160 155 x 81 x 186 180 x 88 x 220

HR-series 7 A B C D E HR10-20 550 640 800 - - HR30-40 665 815 990 1200 1200 HR50-60 - - - 1200 1200 HR80-120 - - - 1357 1600 1 3 2 6 6 6 4 5 clamps for H-section HR30-120 HR10-20 HR30-120 HR30-60 (optional) HR10-40 front view HR10-20 top view HR10-20 top view HR30-120 front view HR30-120 14 Winterwarm HR-series The condensing unit air heater which combines efficient heating with energy savings and high comfort. The whole serie complies with the strict ErP regulations which have come into effect as of 2021. Characteristics • high efficiency • energy saving (up to 25% compared to conventional heaters) • SS Heatexchanger as standard • modulating burner • compact • option to suspend the heater under an angle of max. 45° (HR10- HR60) • easy to install • modulating clock thermostat • optional: control by 0-10 V or by modbus • IP20B • delivery incl. siphon for condensate B A Aa I I J C F H M10 M10 M10 M10 M10 Gas O Flue outlet Ø N Air inlet Ø M B A Aa I I J C F H M10 M10 M10 M10 M10 Gas O Flue outlet Ø N Air inlet Ø M HR 30 - 120 HR 30 - 40 ø130 ø130 HR 30 - 120 HR 30 - 40 Measurements A Aa B C F H I J M N O P Q HR10-20 650 755 495 530 470 400 325 280 ø80 ø80 1/2” 415 420 HR30 795 - 670 650 545 470 400 325 ø80 ø80 3/4” 575 565 HR40 795 - 670 650 545 470 400 325 ø80 ø80 3/4” 575 565 HR50-60 1065 - 670 650 815 470 - - ø80 ø80 3/4” 840 565 HR80-100 1135 - 1040 1010 822 700 - - 100 100 1” 855 935 HR120 1280 - 1040 1010 972 700 - - 130 130 1” 1005 935 B A a Gas O Flue outlet Ø N Air inlet Ø M O 1/2" 1/2" 1/2" 1/2" A B C F H I M10 M10 M10 M10 Gas Ø O Flue outlet Ø N Air inlet Ø M 8 rear view HR10-20 rear view HR30-60 rear view HR80-120 Fanbox with dampers top/rear or bottom/rear - HR30 - HR60

15 1 2 3 4 4 5 5 6 6 7 8 Accessories HR-series Controls (more information on page 36) applicable on article no. price € Multitherm S roomthermostat for 1-8 heaters HR10-HR120 IX3911 189 Multitherm C clockthermostat for 1-8 heaters HR10-HR120 IX3912 364 Remote Sensor, optional with MTC HR10-HR120 GA3929 141 Interface Board for connection to a BMS (max. 8 heaters) HR10-HR120 IB5902 364 Modbus control set (for building management system) HR10-HR120 GA5903 76 0-10 V. input control set HR10-HR120 GA5906 76 Power isolation switch, 230 V - 400 V, 25 Amp. HR10-HR120 IK5281 82 Set external alarm signal HR10-HR120 GA4009 29 Set external alarm signal and reset HR10-HR120 GA4012 142 Service parts box for HR HR10-HR120 GA4002-1 1169 Suspension Suspension brackets HR10-HR20 GA8610 195 Suspension brackets HR30-HR40 GA8620 217 Clampset for mounting to H-profile (combined with GA8610, GA8620, GA8630) HR10-HR40 GA8680 141 Clampset for mounting to H-profile (combined with GA8580) HR30-HR60 GA8685 364 Cantilever brackets M (per set) HR30-HR60 GA8580 204 Cantilever brackets L (per set) HR80-HR120 GA8622 284 Design suspension HR10-HR20 GA8630 301 Additional Set vertical louvres (4 pcs.) HR10-HR20 GX2001 126 Set vertical louvres (4 pcs.) HR30-HR40 GX4001 159 Set vertical louvres (6 pcs.) HR50-HR60 GX6002 194 Set vertical louvres (5 pcs.) HR80-HR120 GX8010 207 Condensate pump set incl. sifon adapter, hose connector, hose to waiste soil pipe, and 6 m. hose for condensate discharge HR10-HR120 GX8002 357 Hose for condensate discharge 30m., ø10mm HR10-HR120 IK5785 63 Fanbox HR for outside air entry, incl. connection piece and 2 dampers HR30-HR60 GAX60110 1014 Servomotor 220V for dampers on fanbox HR30-HR60 IK4800 695 Remote step control for servomotor HR30-HR60 GA4801 274 For flue material see page 20/21 Technical data HR-series Type Unit HR10 HR20 HR30 HR40 HR50 HR60 HR80 HR100 HR120 Price gasfired* condensing air heater, natural gas € 3600 4045 4590 5580 6320 7155 7545 9295 10980 Price gasfired* condensing air heater, propane € 3710 4185 4760 5750 6590 7425 7640 9385 11070 Maximum nominal heat input (H.I.) kW 12,5 20,0 30,0 40,0 50,0 60,0 72,0 91,0 111,0 Minimum nominal heat input (H.I.) kW 4,0 6,0 9,0 12,0 15,0 18,0 24,0 25,0 32,0 Efficiency max. power % 96,0 96,0 96,5 97,0 96,5 96,6 97,0 96,3 96,9 Efficiency 30% power % 106,0 106,0 106,0 106,5 106,0 106,0 106,0 106,0 106,0 Maximum heat output kW 12,0 19,2 29,0 38,8 48,3 58,0 69,8 88,3 107,7 Minimum heat output kW 4,2 6,4 9,5 12,8 15,9 19,1 25,4 26,5 38,2 Throw horizontal (max) m 15 20 23 26 28 30 42 48 49 Electrical Voltage (50 Hz) V 230 230 230 230 230 230 230 230 230 Electrical power W 250 250 250 450 450 600 780 790 1240 Electrical current A 1,1 1,1 1,2 2,0 2,6 2,6 3,5 3,7 5,5 Max air output (warm) m3/h 2000 2600 3000 4500 6400 6800 11000 12900 14600 Sound level (@ 4 meter), range dB(A) 56-58 56-58 56-58 57-61 61-64 61-64 56-61 56-61 56-62 Weight kg 45 50 75 85 105 110 190 200 225 Max gas consumption (G20) m3/h 1,3 2,1 3,2 4,2 5,3 6,3 7,6 9,6 11,7 Max gas consumption (G31) kg/h 1,0 1,6 2,4 3,2 4,0 4,8 5,8 7,3 8,9 Gas connection G” 1/2 1/2 3/4 3/4 3/4 3/4 1 1 1 Minimum suspension height horizontal throw m 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 Max. length flue** m 9 9 9 9 9 9 9 9 9 *) HR, gasfired condensing air heater, 45 degrees downwards, on request **) for each 90º elbow, 2m. less; for each 45º elbow, 1 m. less.

HR EC-series 7 3 A B C D E HR10-20 550 640 800 - - HR30-40 665 815 990 1200 1200 HR50-60 - - - 1200 1200 HR80-120 - - - 1357 1600 1 2 6 6 6 5 HR30-120 HR10-20 HR30-120 HR10-40 HR30-60 (optie) Winterwarm HR EC-series The most sustainable unit air heater from Winterwarm is the HR EC-series. These heaters are not only highly efficient as far as gas consumption is concerned, but also have a low electricity consunption and a low sound level because of the EC fan motor. Characteristics • high efficiency • energy saving (low gas consumption ánd low electricity consumption) • SS Heatexchanger as standard • modulating burner • compact • option to suspend the heater under an angle of max. 45° (HR10 - HR60) • easy to install • modulating clock thermostat • optional: control by 0-10 V or by modbus • very quiet • IP20B • delivery incl. siphon for condensate 16 4 B A Aa I I J C F H M10 M10 M10 M10 M10 Gas O Flue outlet Ø N Air inlet Ø M B A Aa I I J C F H M10 M10 M10 M10 M10 Gas O Flue outlet Ø N Air inlet Ø M HR 30 - 120 HR 30 - 40 ø130 ø130 HR 30 - 120 HR 30 - 40 A Aa B C F H I J M N O P Q HR10-20EC 650 755 495 530 470 400 325 280 ø80 ø80 1/2” 415 420 HR30EC 795 - 670 650 545 470 400 325 ø80 ø80 3/4” 575 565 HR40EC 795 - 670 650 545 470 400 325 ø80 ø80 3/4” 575 565 HR50-60EC 1065 - 670 650 815 470 - - ø80 ø80 3/4” 840 565 HR80-100EC 1135 - 1040 1010 822 700 235 155 100 100 1” 855 935 HR120EC 1280 - 1040 1010 972 700 235 155 130 130 1” 1005 935 Measurements B A a Gas O Flue outlet Ø N Air inlet Ø M O 1/2" 1/2" 1/2" 1/2" A B C F H I M10 M10 M10 M10 Gas Ø O Flue outlet Ø N Air inlet Ø M 8 clamps for H-section front view HR10-20 top view HR10-20 top view HR30-120 front view HR30-120 rear view HR10-20 rear view HR30-60 rear view HR80-120 Fanbox with dampers top/rear or bottom/rear - HR30-HR60 Sustainable choice

17 1 2 3 4 4 5 5 6 6 7 8 Accessories HR EC-series Controls (more information on page 36) applicable on article no. price € Multitherm S roomthermostat for 1-8 heaters HR10-HR120 IX3911 189 Multitherm C clockthermostat for 1-8 heaters HR10-HR120 IX3912 364 Remote Sensor, optional with MTC HR10-HR120 GA3929 141 Interface Board for connection to a BMS (max. 8 heaters) HR10-HR120 IB5902 364 Modbus control set HR10-HR120 GA5903 76 0-10 V. input control set HR10-HR120 GA5906 76 Power isolation switch, 230 V - 400 V, 25 Amp. HR10-HR120 IK5281 82 Set extern alarm signaal HR10-HR120 GA4009 29 Set external alarm signal and reset HR10-HR120 GA4012 142 Service parts box for HR HR10-HR120 GA4002-1 1169 Suspension Suspension brackets S HR10-HR20 GA8610 195 Suspension brackets M HR30-HR40 GA8620 217 Clampset for mounting to H-profile (combined with GA8610, GA8620, GA8630) HR10-HR40 GA8680 141 Clampset for mounting to H-profile (combined with GA8580) HR30-HR120 GA8685 364 Cantilever brackets (per set) M HR30-HR60 GA8580 204 Cantilever brackets L (wall suspension) HR80-HR120 GA8622 284 Design suspension HR10-HR20 GA8630 301 Additional Set vertical louvres (4 pcs.) HR10-HR20 GX2001 126 Set vertical louvres (4 pcs.) HR30-HR40 GX4001 159 Set vertical louvres (6 pcs.) HR50-HR60 GX6002 194 Set vertical louvres (5 pcs.) HR80-HR120 GX8010 207 Condensate pump set incl. sifon adapter, hose connector, hose to waiste soil pipe, and 6 m. hose for condensate discharge HR10-HR120 GX8002 357 Hose for condensate discharge 30m., ø10mm HR10-HR120 IK5785 63 Fanbox HR for outside air entry, incl. connection piece and 2 dampers HR30-HR60 GAX60110 1014 Servomotor 220V for dampers on fanbox HR30-HR60 IK4800 695 Remote step control for servomotor HR30-HR60 GA4801 274 For flue material see page 20/21 Technical data HR EC-series Type Unit HR10EC HR20EC HR30EC HR40EC HR50EC HR60EC HR80EC HR100EC HR120EC Price horizontal* throw natural gas € 4120 4580 5115 6125 7010 7940 8840 10670 12460 Price horizontal* throw propane € 4230 4720 5305 6320 7270 8215 8990 10810 12605 Maximum nominal heat input (H.I.) kW 12,5 20,0 30,0 40,0 50,0 60,0 72,0 91,0 111,0 Minimum nominal heat input (H.I.) kW 4,0 6,0 9,0 12,0 15,0 18,0 24,0 25,0 32,0 Efficiency max. power % 96,0 96,0 96,5 97,0 96,5 96,6 97,0 96,3 96,9 Efficiency 30% power % 106 106 106 106 106 106 106 106 106 Maximum heat output kW 12,0 19,2 29,0 38,8 48,3 58,0 69,8 88,3 107,7 Minimum heat output kW 4,2 6,4 9,5 12,8 15,9 19,1 25,4 26,5 38,2 Throw horizontal m 15 20 23 26 28 30 42 48 49 Voltage (50Hz) V 230 230 230 230 230 230 230 230 230 Elektrical power W 160 160 175 260 475 500 750 830 1100 Elektrical current A 1,3 1,3 1,6 1,2 2,3 2,5 3,4 3,8 5,1 Air output high (warm) m3/h 2200 2650 3150 4500 6700 6700 12400 13500 15400 Air output low (warm) m3/h 1600 1700 1900 2500 4000 4000 10500 13200 11100 Sound level (@ 4 meter) dB(A) 42-54 42-54 43-55 47-62 48-64 48-64 50-60 50-60 56-61 Weight kg 45 50 75 85 105 110 190 200 225 Gas consumption natural gas (G20) m3/h 1,3 2,1 3,2 4,2 5,3 6,3 7,6 9,6 11,7 Gas consumption propane (G31) kg/h 1,0 1,6 2,4 3,2 4,0 4,8 5,8 7,3 8,9 Gas connection G” 1/2 1/2 3/4 3/4 3/4 3/4 1 1 1 Min. suspension height hor. throw m 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 Max. length flue vertical and horizontal** m 9 9 9 9 9 9 9 9 9 *) HR, gasfired condensing air heater, 45 degrees downwards, on request **) for each 90º elbow, 2m. less; for each 45º elbow, 1 m. less. Condensation exhaust necessary when flue > 4m

airlift effect 8 4 7 6 clamps for H-section A B C D XR 10+/30+ 550 640 830 540 XR 40+/60+ 665 815 990 720 D E XR 40+/60+ 1200 1200 XR 80+/120+ 1357 1600 1 3 2 5 XR40+ - XR100+ XR+ series 16 Winterwarm XR+ series Winterwarm presents the XR+ range: a complete upgrade from the well-known XR unit air heaters which comply with the ErP2021 directive. A non-condensing gas fired heater with improved performance for a comfortable and efficient heating of industrial and commercial buildings. Characteristics XR+: • compact and reduced weight • non-condensing (no condensate drain necessary) • flexible airflow direction, incl. vertical • inverted heat exchanger gives more even air temperature • increased air volume • delta-T control • modulating premix burner and fan • control up to 8 heaters with one thermostat • optional: control by 0-10 V or by modbus • protection degree IP20B more information on controls on page 36 4 & 8 vertical and horizontal suspension possible. Measurements XR40+ - XR60+ XR80+ - XR120+ XR10+ - XR30+ F H I C M10 M10 M10 M10 A B Gas O Left view Right view J A Aa B C F H I J M N O XR40+ 795 - 670 650 546 470 400 325 80 80 3/4" XR50+ 795 - 670 650 545 470 400 325 80 80 3/4" XR60+ 795 - 670 650 545 470 400 325 80 80 3/4" A B C F H J I M10 M10 M10 M10 Flue outlet Ø N Air inlet Ø M Gas Ø O Aanzichten + afmetingen HR80 - 120 serie A B C H J F I Gas Ø O Air inlet Ø M Flue outlet Ø N M10 M10 M10 M10 Aanzichten + afmetingen XR80+ - XR120+ serie Aa B A C J I F H M10 M10 M10 M10 M10 Gas O Flue outlet Ø N Air inlet Ø M I Left view Right view A Aa B C F H M N O XR10+ 650 755 495 530 470 400 80 80 1/2" XR20+ 650 755 495 530 470 400 80 80 1/2" XR30/35+ 650 755 495 530 470 400 80 80 1/2" A Aa B C F H I J M N O XR10+-XR30+ 650 755 495 530 470 400 325 280 80 80 1/2” XR40+-XR60+ 795 - 670 650 546 470 400 325 80 80 3/4” XR80+-XR100+ 1135 - 1040 1010 822 700 235 155 100 100 1” XR120+ 1280 - 1040 1010 972 700 235 155 130 130 1” 9 Fanbox with dampers top/rear or bottom/rear

19 Technical data XR+ series Type Eenheid XR 10+ XR 20+ XR 30+ XR 40+ XR 50+ XR 60+ XR 80+ XR 100+ XR 120+ Price natural gas € 2890 3230 3665 4495 5065 5725 6855 7815 9380 Price propane € 2970 3375 3865 4630 5325 5995 6945 7905 9480 Nominal heat input max. (h.i.) kW 14,0 22,8 32,0 44,0 55,0 66,0 72,0 91,0 111,0 Nominal heat input min, (h.i.) kW 8,5 13,5 18,0 26,4 33,0 39,6 48,0 60,0 72,0 Maximum efficiency % 93,8 94,6 94,6 95,8 95,6 95,6 95,9 96,0 96,4 Maximum heat output kW 12,7 20,7 28,9 41,1 50,7 61,2 68,6 86,9 105,6 Minimum heat output kW 8,0 12,8 17,0 25,3 31,5 37,9 46,0 57,6 69,4 Air output (warm) m3/h 2,750 4,000 4,200 5,400 8,000 8,000 10,200 10,700 13,000 Throw horizontal m 22 30 31 32 46 46 38 40 43 Throw vertical (warm) m 5 5 6 7 7 8 - - - Voltage (50Hz) V 230 230 230 230 230 230 230 230 230 Electrical power W 200 300 300 325 750 750 730 760 1,210 Electrical current A 0,9 1,4 1,4 1,5 3,5 3,5 3,3 3,5 6 Sound level (@ 5 meter) dB(A) 54-56 56-59 56-59 54-59 58-64 58-64 58-62 58-62 58-62 Weight kg 46 50 53 78 80 82 185 195 215 Gas consumption natural gas (G20) m3/h 1,5 2,4 3,4 4,7 5,8 7,0 7,6 9,6 11,7 Gas consumption propane (G31) kg/h 1,1 1,8 2,5 3,5 4,4 5,3 5,8 7,3 8,9 Gas connection G” 1/2 1/2 1/2 3/4 3/4 3/4 1”bi 1”bi 1”bi Min, suspension height horizontal throw m 1,7 1,7 1,7 2,7 2,7 2,7 2,7 2,7 2,7 Min. suspension height vertical throw m 4 4 4 5 6 6 - - - Max. length flue hor, throw m 6 6 6 8 8 8 9 9 9 Max. length flue vert, throw m 2 2 2 2 2 2 - - - *) for each 90º elbow, 2m. less; for each 45º elbow, 1 m. less. Condensation exhaust necessary when flue > 4m 1 2 3 4 4 5 6 5 7 8 Accessories XR+ series Controls (more information on page 36) applicable on article no. price € MultiTherm S thermostat for 1-8 unit air heaters with external enable/disable option XR10+ - XR120+ IX3911 189 MultiTherm C clock thermostat for 1-8 unit air heaters XR10+ - XR120+ IX3912 364 Remote sensor, optional with MTC XR10+ - XR120+ GA3929 141 Interface board for connection to a BMS (max. 8 heaters) XR10+ - XR120+ IB5902 364 MTS with extra input relay XR10+ - XR120+ GX3955 256 MTC with extra input relay XR10+ - XR120+ GX3956 468 Power isolation switch, 230 V - 400 V, 25 Amp. XR10+ - XR120+ IK5281 82 Service parts box for XR+ XR10+ - XR120+ GA4002-1 1169 Modbus control set XR10+ - XR120+ GA5903 76 0-10 V. input control set XR10+ - XR120+ GA5906 76 Set extern alarm signal XR10+ - XR120+ GA4009 29 Set external alarm signal and reset XR10+ - XR120+ GA4012 142 Suspension Suspension brackets S (wall- or ceiling suspension) XR10+ - XR30+ GA8610 195 Suspension brackets M (wall- or ceiling suspension) XR40+ - XR60+ GA8620 217 Cantilever brackets M (wall suspension) XR40+ - XR60+ GA8580 204 Cantilever brackets L (wall suspension) XR80+ - XR120+ GA8622 284 Clamps for H-section, together with GA8580 XR10+ - XR60+ GA8680 141 Vertical suspension kit 80-165 cm XR10+ - XR60+ GA8645 217 Design suspension XR10+ - XR30+ GA8630 301 Additional Set vertical louvres (4 pcs) XR10+ - XR30+ GX2001 126 Set vertical louvres (4 pcs) XR40+ - XR60+ GX4001 159 Set vertical louvres (6 pcs) XR80+ - XR80+ GX8010 207 Fanbox HR for outside air entry, incl. connection piece and 2 dampers XR40+ - XR60+ GAX60110 1014 Servomotor 220V for dampers on fanbox XR40+ - XR60+ IK4800 695 Remote step control for servomotor XR40+ - XR60+ GA4801 274 For flue material see page 20/21 9

20 ød øD HOH A B Cmin. E F HR 10-60 80 125 110 1370 575 500 610 135 HR 80-100 100 150 140 1551 930 700 610 175 HR 120 130 200 225 1745 930 730 750 300 QSG 80 125 110 1370 575 500 610 135 Flue materials Flue terminals All Winterwarm gas fired unit air heaters are CE-approved with their own flue terminal system. These should be ordered together with the heater (roof or wall terminal). For HR/HR-EC unit air heaters and QSG booster units For XR+ unit air heaters Easy Fix: fits exactly No extra parts necessary A Ø D Ø d HOH B C min Ø d Ø D E F Max. 300 XR10+ - XR30+ XR10+ - XR30+ XR10+ - XR60+ XR10+ - XR30+ XR40+ - XR120+ XR40+ - XR120+ XR10+ - XR30+ ød øD HOH A B Cmin. E F XR10+ / XR60+ 80 125 110 1200 400 500 610 180 XR80+ / XR100+ 100 150 140 1200 500 600 610 180 XR120+ 130 200 225 1850 955 - 750 190 HR/HR-EC 10-60 HR/HR-EC 80-120

Flue materials Various flue materials Winterwarm offers extra flue material to extend the flue system and different kinds of roof sheets. Type (aluminium 0,7mm - T200 for XR+ series) diameter article no. price € Elbow 90° Ø 80 IA8123 21 Elbow 45° Ø 80 IA8200 19 Pipe 1000 mm Ø 80 IA8128 34 Pipe 500 mm Ø 80 IA8250 24 Elbow 90º Ø 100 IA8167 28 Elbow 45º Ø 100 IA8163 22 Pipe 1000 mm Ø 100 IA8156 40 Pipe 500 mm Ø 100 IA8150 26 Elbow 90° Ø 130 IA8367 46 Elbow 45° Ø 130 IA8363 42 Pipe 1000 mm Ø 130 IA8356 54 Pipe 500 mm Ø 130 IA8350 44 Type (aluminium 1,5mm - T120 for HR-series) diameter article no. price € Elbow 90° Ø 80 IA8220 27 Elbow 45° Ø 80 IA8221 27 Pipe 1000 mm Ø 80 IA8129 44 Pipe 500 mm Ø 80 IA8222 25 Elbow 90º Ø 100 IA8168 40 Elbow 45º Ø 100 IA8162 32 Pipe 1000 mm Ø 100 IA8158 57 Pipe 500 mm Ø 100 IA8152 38 Elbow 90° Ø 130 IA8368 110 Elbow 45° Ø 130 IA8362 72 Elbow 30° Ø 130 IA8360 122 Pipe 1000 mm Ø 130 IA8358 83 Pipe 500 mm Ø 130 IA8352 53 article no. price € Concentric extension pipe, beneath the roof IA8313 168 Concentric extension pipe, above the roof IA8411 291 Roof sheet RP 80/125 IA8121 23 Roof sheet RP 100/150 IA8321 42 Conical roof sheet CP (45°) CL 100/160 incl. storm collar GA8142 462 Roof sheet RP 130/210 IA8322 48 Adjustable roofsheet 130/200 (25°-55°) IA8341 314 Conical roof sheet CP 130/210 (up to 45º), incl. storm collar GA8332 440 Roof sheet set 130/210 for trapezodial roof GA8334 257 Flue material for HR series and QSG-series applicable on article no. price € DDV 80/125 HR Roofterminal HR10-HR60 + QSG IA8214 175 CT 80/125 HR Wall terminal HR10-HR60 + QSG IA8216 149 DDV 100/150 HR HR80-HR100 IA8108 396 CT 100/150 HR HR80-HR100 IA8114 257 DDV 130/210 HR Roofterminal HR120 IA8307 631 CT 130/210 HR Wall terminal HR120 IA8314 476 Flue material for XR series applicable on article no. price € Roof terminal DDV 80/125 XR10+ - XR60+ IA8202 218 Wall terminal MDV 80 (2-pipes) XR10+ - XR60+ IA8212 195 Concentric wall terminal CT 80/125 XR10+ - XR60+ IA8113 153 Easy Fix wall terminal XR10+ - XR30+ GA8201 280 Roof terminal DDV 100/150 XR80+ - XR100+ IA8101 316 Concentric wall terminal CT 100/150 XR80+ - XR100+ IA8112 257 Roof terminal DDV 130/200 XR120+ IA8305 537 Concentric wall terminal CT 130/200 XR120+ IA8312 353 21

22 ACM-series Measurements Maximum distance to the wall (possibility to place roller blind in between) One assembly set per air curtain Example for a door of 5.00 m: Top view Front view Width 5010 mm. (When more than 10 modules are necessary, extra support is required.) Winterwarm ACM Winterwarm presents a modular air curtain. The modular construction enables you to assemble an air curtain for each door width. The ACM creates a comfortable room climate, prevents drafts and intrusion of polluted outside air. Characteristics: • applicable for all doors with a height of 4,5 m. or less • modular construction • vertical and horizontal positioning possible • possibility to place underneath overhead-door • high air output • innovative application of Gurney flap which results in a relative high-air speed at floor level • adjustable louvres to create optimum air flow • low weight 5 6 1 2 600 806 4 3 Vertical mounting set Attention: in vertical position the air curtain is less effective. Sustainable choice

Technical data ACM-series Number of modules Unit 1 4 5 6 7 8 9 10 Length incl. endplates* mm 520 2020 2520 3020 3520 4020 4520 5020 Max. suspension height m 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 Air output m3/h 1,900 7,600 9,500 11,400 13,300 15,200 17,100 19,000 Voltage (50 Hz) V 230 230 230 230 230 230 230 230 Accumulated power consumption** A 1.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Sound level (@ 5 meter) dB(A) 64 70 71 72 73 73 73 74 Weight kg 12 48 60 72 84 96 108 120 23 The aircurtain is keeping the cold air out, and contributes to the realisation of the required room temperature because the warm air underneath the sealing is transported downwards. 1 3 2 4 5 5 5 5 Accessories ACM-series Description article no. price € Heater module ACM* GVACM 565 Assembly set (incl. 2 end plates and 1 connector) GA8700 67 Per air curtain one assembly set is required Vertical mounting set (incl. bottom plate and 2 support strips) GA8585 63 Horizontal mounting consoles (max. 10 modules per set) GA8575 224 5-step switch 5 Amp. IA8543 350 5-step switch 8 Amp. IA8544 464 5-step switch 11 Amp. IA8515 596 5-step switch 15 Amp. IA8516 967 Relay for door contact, 230 V., 20 Amp. GA4100 139 *) The width of the door determines the number of modules to order. 6 Side view air flow

WCU-series 24 Destratification fans Nowadays buildings are well insulated; this limits the required heating capacity in a room. In this situation, however, it is very important to achieve a good recirculation of the warm air in the room by installing destratification fans. The installation of a destratification fan pays for itself quickly because of the significant energy savings. All WCU models are available with EC-motor which reduces the electricity consumption with 25%. Winterwarm has 2 types of destratification fans: recirculation unit WCU and a 3-blade ceiling fan Rendovent. Characteristics destratification fans: • extra circulation of warm air • reduced heat losses • increased comfort • temperature gradient drops • energy savings • WCU IP30 • Rendovent IP20 • option: EC motor • stepless control air volume (WCU-EC) provided with 4 suspension screws ø10 mm 1 5 WCU, for installation in rooms from 5 to 12 m. high Recirculation unit WCU Ceiling fan Rendovent Typical installations Install destratification fans always at the end of the throw (to prevent air swirls) or above a location which is not reached by the air current of the heater. The WCU fans are all as standard provided with a room thermostat 230 V. and a socket connector. Measurements WCU (in mm) Type 40 60 80 100 A 470 600 600 800 B 470 600 600 800 C 289 319 328 438 C (voor EC) 255 269 269 396 D 300 375 400 740 Measurements 6 2 3 Total height 69 cm. Sustainable choice

s Technical data destratification fans Type Unit WCU40 WCU60 WCU80 WCU100 WCU40EC WCU60EC WCU80EC WCU100EC Rendovent black/white Price € 805 950 1235 1500 1140 1550 1915 2415 265 Air output m3/h 3,200 5,600 7,000 10,000 3,300 5,700 7,000 10,000 13,000 Diameter fan mm 350 450 500 650 350 450 450 650 1420 Distance fan to ceiling cm 35 45 50 65 35 45 50 65 65 Throw vertical m 5-8 7-10 8-12 12-15 5-9 7-11 8-12 12-15 3-7 Voltage (50Hz) V 230 230 230 230 230 230 230 230 230 Electrical power W 155 290 400 480 136 320 490 550 75 Electrical current A 0,75 1,3 1,85 2,1 1,1 1,4 2,1 2,5 0,35 Revolutions per minute rpm 1,380 1,360 1,315 1,000 1,530 1,300 1,500 1,050 300 Sound level (@ 6 mtr), range dB(A) 33-56 35-59 37-59 39-58 33-55 33-59 37-59 37-55 36 Sound level (@ 8 mtr), range dB(A) 31-54 33-57 35-57 37-56 31-53 31-57 35-57 35-53 - Weight kg 11 18 18 43 11 18 18 43 9,5 For rooms with more than 5 m. height, Winterwarm advises to always install destratification fans; rule of thumb is 1 per 300 m2*. Room volume m3 <1.000 2.000 3.000 5.000 7.000 9.000 12.000 Minimal desired recirculation 6 5 4 3 2.5 2 2 multiple* 1 2 2 3 4 4 4 4 4 5 4 25 Advantages application destratification fans: • Temperature gradient drops • Heat transmission loss reduces • Energy savings (20 to 30%!) • Higher comfort • Extra air circulation in the summer • Easy to install Without application of destratification fans the temperature gradient increases with 1,3°C per 1 m. height* (in order to determine the number of necessary destratification fans, add the air output of the heater to that of the destratification fan(s)) *) Source: ISSO publication 57 Accessories WCU-series Type article no. price € Suspension set WCU GA8570 46 Room thermostat on/off 230V, 10 Amp., IP30 IW3950 51 Room thermostat on/off 230V, 10-200 mAmp., IP30 for WCU EC IW3961 51 Stepless switch 3 Amp. (for 1-7 Rendovents) IA8509 185 5-step switch 2.2 Amp. IA8540 309 5-step switch 3.5 Amp. IA8542 320 5-step switch 5.0 Amp. IA8543 350 5-step switch 8.0 Amp. IA8544 464 5-step switch 11 Amp. IA8515 596 5-step switch 15 Amp. IA8516 967 Stepless speed controller 0-10 V., for WCU-EC GA3955 118 Switch relay set (for simultaneous operation with heaters) GX3952 86

WWH-series 26 Discharge possibilities standard grill 4-way downflow plenum vertical louvres 4 1 2 8 6 7 5 Type 1 2 A 711 846 B 640 814 C 583 694 D 391 392 E 148 150 Measurements The range of 10-80 kW is subdivided in 3 models. The model of the heater is the first number of the type name (1,2 or 3). WWH-series Winterwarm presents the WWH-series: LPHW heaters which, combined with any type of hot water system, can comfortably heat up any room. Characteristics WWH: • good air circulation • comfortable temperature distribution • various air discharge possibilities • can be installed anywhere • 7 capacities available • simple to control • long duration of life • 10 suspension points • IP54 • available with HPX heat pump Sustainable choice 3 Type 110 115 120 230 235 245 350 Bouwgrootte 1 1 1 2 2 2 3 A 510.5 510.5 510.5 692.5 692.5 692.5 863.5 B 509 509 509 693 693 693 864 C 46.5 46.5 44 34 34 42 33 D 435.5 435.5 435.5 585 585 585 756 E 435 435 435 585 585 585 756 F 3/4’’ 3/4’’ 3/4’’ 3/4’’ 3/4’’ 1’’ 1’’ G 91.7 91.7 72.7 93.5 93.5 82.7 107.2 H 327 327 346 504.5 504.5 515.5 652 I 91.7 91.7 91.7 94.5 94.5 94.2 104.2 J 320 320 320 363 363 363 357.5 K 45 45 45 83 83 83 66.8 L 70 70 69 86 86 86 93 M 39 39 44 43.5 43.5 45 35 N 54.5 54.5 54.5 76.5 76.5 76.5 87 O 160 160 160 160 160 160 160 P 80 80 80 101 101 101 78 Q 254.5 254.5 254.5 346.5 346.5 346.5 432 R 160 160 160 181 181 181 158

1 2 4 3 5 6 27 8 8 7 8 8 8 8 Accessories WWH-series Description 110 115 120 230 235 245 350 Article no. GA8595 GA8595 GA8595 GA8595 GA8595 GA8595 GA8595 Wall brackets 84 84 84 84 84 84 84 Article no. GA8600 GA8600 GA8600 GA8600 GA8600 GA8600 GA8600 Ceiling suspension set 75 71 75 75 75 75 75 Article no. GA8610 GA8610 GA8610 GA8620 GA8620 GA8620 - Suspension brackets 195 195 217 217 217 217 - Article no. GA120WW-1 GA120WW-1 GA120WW-1 GA245WW-1 GA245WW-1 GA245WW-1 GA380WW-1 4-way down flow plenum 147 147 179 179 179 179 226 Article no. GA120VS-1 GA120VS-1 GA120VS-1 GA245VS-1 GA245VS-1 GA245VS-1 GA380VS-1 Set vertical louvres 79/5 pc. 79/5 pc. 79/5 pc. 105/6 pc. 105/6 pc. 105/6 pc. 126/6 pc. Controls (more information on page 36) article no. price € Room thermostat 230 V-10 Amp.- on/off IW3950 52 Clock thermostat 230V, 10 Amp. . IW3968 383 Connection thermostat IH8500 48 5-step switch 2.2 Amp. IA8540 309 5-step switch 3.5 Amp. IA8542 320 5-step switch 5.0 Amp. IA8543 350 5-step switch 8 Amp. IA8544 464 5-step switch 11 Amp. IA8515 596 5-step switch 15 Amp. IA8516 967 Zone valve, 230V, 3/4” (2-way) GA3980 543 Technical data WWH-series Type Unit 110 115 120 230 235 245 350 Price € 800 880 1025 1235 1345 1555 1695 Maximum heat output* kW 11,7 14,7 19,5 22,8 27,7 38,7 48,2 Air output (warm) m3/h 1,400 2,200 1,900 2,600 3,850 3,450 6,600 Throw horizontal m 10 14 12 19 22 19 20 Throw vertical m 3.5 5 4 6 7 6 7 Voltage (50Hz) V 230 230 230 230 230 230 230 Electrical power* W 165 165 165 350 350 350 680 Electrical current* A 0,75 0,75 0,75 1,5 1,5 1,5 3,0 Sound level (@ 5 meter) dB(A) 50 59 58 51 61 60 62 Weight (incl. water) kg 20 20 21 31 31 32 44 Water connection G” 3/4 3/4 3/4 3/4 3/4 1 1 Watersided pressure loss kPa 2 3 3 3 3 5 4 Minimum suspension height m 2,5 2,5 2,5 2,5 2,5 2,5 2,5 *) at water temperature 90/70° and room temperature 15ºC Capacities @ various water temperatures In situations with other water temperatures, one has to multiply the standard capacity of the unit with the value in the table below. The WWH-range is not suitable for application with steam. Air temperature inlet Water temperature 0ºC 5ºC 10ºC 15ºC 18ºC 20ºC 90/70ºC 1,30 1,19 1,10 1,00 0,94 0,91 80/60ºC 1,11 1,01 0,91 0,82 0,76 0,73 70/50ºC 0,92 0,82 0,73 0,64 0,56 0,55 60/40ºC 0,73 0,64 0,54 0,45 0,40 0,37 50/30ºC 0,54 0,45 0,37 0,27 0,22 0,18

RkJQdWJsaXNoZXIy MTE2OTgy